FD Decoders

FD-101

Specifications

Model: FD-101 single field decoder (1 address, 1 solenoid)
Mounting: In valve box or direct burial
Power Draw: 0.5 mA (idle) 18 mA (Per active valve)
Dimensions:
Length: 57 mm, Diameter: 40 mm
Station: 1
Wires: Blue to cable, white to solenoid
Output Power: Adjustable from central controller
Encapsulation: Fully waterproof
Address: Precoded from factory (i.e. no switches)
Electrical input:

Nominal voltage: 33 VAC from line
Minimum voltage: 21VAC
Stand by current:0,5mA
Wiring:2x14-gauge(1,5mm2)solid copper,PVC insulateded

Electrical Output:

Max. voltage: 33VAC
Max. load: 1 Rain Bird solenoid

Environment:

Working range: 0 to 50° C
Storage range: -20 to 70° C
Humidity: 100%

FD-102

Specifications

Model: FD-102 single field decoder(1address,up to 2 solenoids)
Mounting: In valve box or direct burial
Power Draw: 0.5mA(idle)18mA(Per active valve)
Dimensions: Length:85mm,Diameter:45mm
Station: 1
Wires: Blue to cable, white to solenoid
Output Power: Adjustable from central controller
Encapsulation: Fully waterproof
Address: Precoded from factory (i.e. no switches)
Electrical input:

Nominal voltage:33 VAC from line
Minimum voltage: 21VAC
Stand by current:0,5mA
Wiring: 2 x 14-gauge (1,5 mm2) solid copper, PVC insulated

Electrical Output:

Max. voltage: 33VAC
Max. load: 2 Rain Bird solenoids

Environment:

Working range: 0 to 50° C
Storage range: -20 to 70° C
Humidity: 100%

FD-202

Specifications

Model: FD-202 dual address field decoder(2 addresses and up to 2 solenoids per address)
Mounting: In valve box
Power Draw: 1 mA (idle) 18 mA (Per active solenoid)
Dimensions:
Length: 85 mm
Diameter: 45 mm
Stations: 2
Wires: Blue to cable,white and brown to solenoids
Output Power: Adjustable from central controller
Encapsulation:  Fully water proof
Address: Precoded from factory (i.e. no switches)
Electrical input:

Nominal voltage: 33VAC from line
Minimum voltage: 21VAC
Standby current: 1,0 mA
Wiring: 2 x 14-gauge (1,5 mm2) solid copper, PVC insulated

Electrical Output:

Max. voltage: 33VAC
Max. load: 4 Rain Bird solenoids (2 per address)

Environment:

Working range: 0 to 50˚C
Storage range: -20 to 70˚C
Humidity: 100%

FD-401

Specifications

Model: FD-401 four-in-one field decoder (4 addresses and 1 solenoid per address)
Mounting: In valve box
Power Draw: 1 mA (idle)18 mA (per active valve)
Dimensions:
Length: 100 mm, Diameter: 65 mm
Stations: 4
Wires: Blue to cable, color-coded to solenoids
Surge Protection: Built-in LSP
Output Power: Adjustable from central controller
Encapsulation: Fully waterproof
Address: Precoded from factory (i.e. no switches)
Electrical Input:

Nominal voltage: 33 VAC from line
Minimum voltage: 21 VAC
Standby current: 1,0 mA
Input fuse: 300-500 mA, thermal
Wiring:2x14-gauge(1,5mm2)solid
copper,PVC insulated

Electrical Output:

Max. voltage: 33 VAC
Max.load: 4 Rain Bird solenoids(1 per address)

Number of Simultaneously
Active Outputs: 4

Environment:
Working range: 0 to 50˚C
Storage range: -20 to 70˚C
Humidity: 100%

 

FD-601

Specifications

Model: FD-601six-in-one field decoder(6 addresses and 1solenoid per address)
Mounting: In valve box
Power Draw: 1 mA (idle) 18 mA (per active valve)
Dimensions:
Length: 100 mm, Diameter: 65 mm
Stations: 6
Wires: Blue to cable, color-coded to solenoids
Surge Protection: Built-in LSP
Output Power: Adjustable from central controller
Encapsulation:  Fully waterproof
Address: Precoded from factory (i.e. no switches)
Electrical Input:

Nominal voltage: 33 VAC from line
Minimum voltage: 21 VAC
Standby current: 1,0 mA
Input fuse: 300-500 mA, thermal
Wiring:2x14-gauge(1,5mm2)solid
copper,PVC insulated

Electrical Output:

Max. voltage: 33 VAC
Max.load:6 Rain Bird solenoids
(1 per address)

Number of Simultaneously
Active Outputs: 4
Environment:

Working range: 0 to 50˚C
Storage range: -20 to 70˚C