EAGLETM 900/950 Series

Closed Case Rotors

For fairways and the rough, the EAGLE™ 900/950 rotor series provides superior coverage.

Closed-Case Provides Proven Debris Resistance

True closed-case construction of EAGLE rotors extends the life of the rotor by protecting the motor from debris, outside elements and environmental changes.

The industry's only self-flushing mode at pop-up and pop-down adds another barrier to debris that is crucial in fine sand and silty soil types. The closed-case design also permits installation to grade.

Specifications

  • Radius:
  • 900 Series: 19,2-29,6 m
  • 950 Series: 21,3-28,0 m
  • Flow rate:
  • 900 Series: 1,35 to 3,60 l/s ; 4,85 to 12,97 m3/h
  • 950 Series: 1,23 to 3,75 l/s ; 4,43 to 13,49 m3/h
  • Arc:
  • 900 Series: Full-circle, 360°
  • 950 Series: Adjustable 40° to 345°
  • Models:
  • EAGLE 900/950 E: Electric valve in-head
  • EAGLE 900/950 S: Stopamatic® (SAM)
  • EAGLE 900/950 IC: Valve in-head, IC module
  • Maximum inlet pressure:
  • Models 900/950 E, IC: 10,3 bars
  • Models 900/950 S: 6,9 bars
  • Pressure regulation range: 4,1 to 6,9 bars
  • Factory pressure settings: 5,6 bars
  • Body Height: 34,0 cm
  • Pop-up Height to nozzle: 8,3 cm
  • Top diameter: 17,8 cm
  • Nozzle Trajectory: 25°
  • Standard nozzle:
  • 900 Series: # 60 black
  • 950 Series: # 28 green
  • Holdback, models S: 4,6 m elevation
  • Rotation Time:
  • 900 Series: 360 ° in 240 seconds; 210 seconds nominally
  • 950 Series: 180°in 120 seconds; 105 seconds nominally
  • Maximum stream Height: 6,1 m
  • Solenoid, E models: 24 VAC 50 cycle solenoid power requirement
  • 0,41 amp inrush current (9,9 VA)
  • 0,30 amp holding current (7,2 VA)
  • Top-serviceable rock screenTM and replaceable Valve seat: All 900/950 models E, S, IC

900 Series

*XX: Nozzle size 44, 48, 52, 56, 60, 64 – Standard nozzle if not
specify 60 black

950 Series

*XX: Nozzle size 18, 20, 22, 24, 26, 28, 30, 32 – Standard nozzle if not specify 28 green

All data are generated from tests conducted in accordance with ASAE Standard S398.1 for at least 30 minutes in zero-wind conditions. Rain Bird recommends the use of SPACE for Windows, equivalent program or derived performance data to optimize nozzle selection.